Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 183
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38389803

RESUMO

Objective: Few reports have explored the application of urinary trypsinogen-2 measurement in the early diagnosis of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis, and none have demonstrated the benefits of noninvasive testing. This study aimed to evaluate the clinical application of the rapid urinary trypsinogen-2 dipstick test (Nipro, Japan) compared with serum amylase and lipase levels for the early diagnosis of post-ERCP pancreatitis (PEP). Methods: A total of 100 consecutive patients (54 men and 46 women) who were admitted and underwent ERCP at Tokyo Medical University Hospital from August 2021 to December 2021 were recruited. All patients underwent rapid urinary trypsinogen-2 measurement using the dipstick test before and after ERCP. Measurements were taken 24 h before ERCP for pre-ERCP and 1-4 h after ERCP for post-ERCP. Additionally, serum amylase and lipase levels were measured at 8:00 a.m. of the day after ERCP (at least 8 h after ERCP), and their diagnostic abilities for PEP were compared and evaluated. Results: PEP occurred in 5/100 patients (5%). The sensitivity, specificity, positive predictive value, and negative predictive value of the dipstick test for diagnosing PEP were 100%, 83.2%, 23.8%, and 100%, respectively. These results were comparable to the diagnostic performance of serum amylase and lipase levels at 8:00 a.m. on the day after ERCP (at least 8 h after ERCP). However, false positives must be considered. Conclusion: The dipstick test may be useful in clinical practice as a noninvasive screening test for the early prediction of PEP.

2.
Diagnostics (Basel) ; 14(2)2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38248007

RESUMO

For pancreatic masses, an evaluation of their vascularity using contrast-enhanced ultrasonography can help improve their characterization. This study was designed to evaluate the utility and safety of contrast-enhanced transabdominal ultrasonography (CE-TUS) and endoscopic ultrasonography (CE-EUS) in the diagnosis of pancreatic masses including solid or cystic masses. This multi-center comparative open-label superiority study is designed to compare Plain (P)-TUS/EUS alone with P-TUS/P-EUS plus CE-TUS/CE-EUS. Three hundred and one patients with a total of 232 solid pancreatic masses and 69 cystic masses were prospectively enrolled. The primary endpoints are to compare the diagnostic accuracy between P-TUS/P-EUS alone and P-TUS/P-EUS plus CE-TUS/CE-EUS for both the TUS and EUS of solid pancreatic masses, and to compare the diagnostic accuracy between P-EUS alone and P-EUS plus CE-EUS in cystic pancreatic masses. The secondary endpoints are to compare the diagnostic sensitivity and specificity of P-TUS/P-EUS alone and P-TUS/P-EUS plus CE-TUS/CE-EUS for pancreatic solid/cystic masses, and the accuracy of P-TUS alone and P-TUS plus CE-TUS for pancreatic cystic masses. Other secondary endpoints included comparing the diagnostic sensitivity, specificity, and accuracy of CE-TUS, CE-EUS and CE-computed tomography (CT) for solid/cystic pancreatic masses. The safety, degree of effective enhancement, and diagnostic confidence obtained with CE-TUS/CE-EUS will also be assessed.

5.
J Hepatobiliary Pancreat Sci ; 31(2): 120-132, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37907717

RESUMO

BACKGROUND/PURPOSE: Afferent loop syndrome (ALS) is a rare adverse event after gastrointestinal surgery requiring appropriate early decompression treatment. Several endoscopic interventions have been attempted for treatment, including endoscopic enteral metal stent placement (EMSP), endoscopic ultrasound (EUS)-guided entero-enterostomy (EUS-EE), and EUS-guided hepaticogastrostomy (EUS-HGS). However, there are limited data on outcomes, including duration of stent patency. In this study, we evaluated the usefulness of each endoscopic intervention for malignant ALS. METHODS: We retrospectively investigated nine patients with malignant ALS who underwent EMSP, EUS-EE, or EUS-HGS. Information on technical success, clinical efficacy, adverse events, stent dysfunction, and overall survival was collected and analyzed. RESULTS: The most common symptoms were abdominal pain and cholangitis. ALS was treated by EMSP in three patients, EUS-EE in three patients, and EUS-HGS in three patients. Stent placement was successful and clinically effective in all patients with no adverse events. During follow-up, stent dysfunction occurred in two patients treated by EUS-HGS. Eight patients died of primary disease during a median follow-up of 157 days. CONCLUSIONS: Each of the available endoscopic interventions for malignant ALS can be expected to produce similar outcomes, including duration of stent patency. The choice of endoscopic intervention should be made based on the characteristics of each treatment.


Assuntos
Síndrome da Alça Aferente , Colestase , Humanos , Estudos Retrospectivos , Síndrome da Alça Aferente/diagnóstico por imagem , Síndrome da Alça Aferente/etiologia , Síndrome da Alça Aferente/cirurgia , Endoscopia , Fígado/patologia , Resultado do Tratamento , Endossonografia , Stents/efeitos adversos , Drenagem , Colestase/etiologia
6.
Gastrointest Endosc ; 99(1): 50-60, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37562548

RESUMO

BACKGROUND AND AIMS: Bilioenteric anastomotic stricture (BES) is a well-known adverse event after bilioenterostomy. Recently, EUS-guided antegrade intervention (EUS-AI) has been developed for cases that are difficult to treat by balloon enteroscopy-assisted ERCP. However, no data are available on the long-term outcomes after EUS-AI. The main goal of the present study was to clarify the long-term outcomes of EUS-AI in such patients. METHODS: Between November 2013 and November 2021, 34 patients who were followed for more than 1 year after EUS-AI for BES were identified. The primary endpoint was the rate of stricture resolution. Secondary endpoints were factors associated with stricture resolution, rate of BES recurrence, rate of conversion to surgery, and rate of hepatic fibrosis progression during follow-up. RESULTS: The median follow-up period was 56.7 months. Stricture resolution was achieved in 17 of 34 patients (50%). A multivariate analysis confirmed that the presence of bile duct stones (odds ratio, 9.473; 95% confidence interval, 1.66-53.98; P = .01) was significantly associated with stricture resolution. The stricture recurrence rate was 33%, and the median time from stent removal to recurrence was 31.2 months. Four patients underwent surgery because of recurrent cholangitis. During the median follow-up period of 56.7 months, 25% progressed to hepatic fibrosis based on the Fibrosis-4 index grade. Interestingly, patients without cholangitis during follow-up did not show progression of hepatic fibrosis. CONCLUSIONS: EUS-AI has achieved acceptable long-term clinical outcomes. EUS-AI can be a viable alternative treatment of choice before surgical treatment in patients who are difficult to treat by conventional approaches.


Assuntos
Colangite , Humanos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estudos Retrospectivos , Colangite/etiologia , Stents/efeitos adversos , Cirrose Hepática , Colangiopancreatografia Retrógrada Endoscópica , Resultado do Tratamento
7.
Medicine (Baltimore) ; 102(44): e35701, 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37933064

RESUMO

INTRODUCTION: In median arcuate ligament syndrome (MALS), the celiac artery is compressed, causing an arcade to develop in the pancreatic head, leading to ischemic symptoms and aneurysms. PATIENT CONCERNS: The patient was diagnosed with borderline resectable pancreatic cancer (PC) and MALS. Endoscopic biliary drainage with a covered metal stent (CMS) was performed for the obstructive jaundice. After the jaundice improved, a modified FOLFIRINOX regimen was initiated. Several days later, cardiopulmonary arrest occurred after hematemesis occurred. Cardiopulmonary resuscitation was performed, his blood pressure stabilized, and emergent upper endoscopy was performed. The CMS was dislodged and active bleeding was observed in the papillae. The CMS was replaced, and temporary hemostasis was achieved. Contrast-enhanced computed tomography revealed a diagnosis of extravasation from the posterior superior pancreaticoduodenal artery (PSPDA) into the biliary tract. Transcatheter arterial embolization was performed. However, the patient was subsequently diagnosed with hypoxic encephalopathy and died on day 14 of hospitalization. DIAGNOSIS: Biliary hemorrhage due to invasion of pancreatic cancer from the PSPDA associated with MALS. INTERVENTION: None. OUTCOMES: Biliary hemorrhage from the PSPDA was fatal in the patient with invasive PC with MALS. LESSONS: Since MALS associated with PC is not a rare disease, the purpose of this study was to keep in mind the possibility of fatal biliary hemorrhage.


Assuntos
Hemobilia , Síndrome do Ligamento Arqueado Mediano , Neoplasias Pancreáticas , Humanos , Protocolos de Quimioterapia Combinada Antineoplásica , Hemobilia/etiologia , Hemorragia/complicações , Síndrome do Ligamento Arqueado Mediano/diagnóstico , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas
8.
Endosc Ultrasound ; 12(2): 251-258, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37148137

RESUMO

Background and Objectives: EUS-guided tissue acquisition is routinely performed for the diagnosis of gastrointestinal tract and adjacent organ lesions. Recently, various types of needles have been developed. However, how the shape of the needle tip and echoendoscope tip angle affect puncturability, has not been clarified. The aim of this experimental study was to compare the puncturability of several 22-gauge EUS-FNA and EUS-guided fine-needle biopsy (EUS-FNB) needles, and to evaluate the effects of the needle tip shape and echoendoscope tip angle on tissue puncturability. Materials and Methods: The following six major FNA and FNB needles were evaluated: SonoTip® ProControl, EZ Shot 3 Plus, Expect™ Standard Handle, SonoTip® TopGain, Acquire™, and SharkCore™. The mean maximum resistance force against needle advancement was evaluated and compared under several conditions using an echoendoscope. Results: The mean maximum resistance force of the needle alone was higher for the FNB needles than for the FNA needles. The mean maximum resistance force of the needle in the echoendoscope with free angle demonstrated that the resistance forces were between 2.10 and 2.34 Newton (N). The mean maximum resistance force increased upon increases in angle of the tip of echoendoscope, particularly in the FNA needles. Among the FNB needles, SharkCore™ had the lowest resistance force (2.23 N). The mean maximum resistance force of the needle alone, the needle in the echoendoscope with free angle, and the needle in the echoendoscope with full-up angle for SonoTip® TopGain were all similar to that of Acquire™. Conclusion: SonoTip® TopGain had similar puncturability to Acquire™ in all tested situations. Regarding the puncturability, SharkCore™ is most suitable for insertion into target lesions, when tight echoendoscope tip angle is necessary.

9.
J Hepatobiliary Pancreat Sci ; 30(3): 351-359, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35918909

RESUMO

BACKGROUND/PURPOSE: Shear wave elastography (SWE) is a clinical method used to evaluate liver hardness. In this study, we assessed its applicability in assessing the pancreas and its potential for diagnosing chronic pancreatitis. METHODS: We performed SWE on 59 patients who underwent abdominal ultrasound, and measured the computed tomography (CT) values of the pancreas. Patients were classified as having a normal pancreas (NP), early chronic pancreatitis (ECP), or chronic pancreatitis (CP). SW elasticity (SWe), SW dispersion (SWd), and CT values between groups were analyzed. RESULTS: SWe significantly differed between the CP and NP/ECP groups (NP vs CP; P = 0.001, ECP vs CP; P = 0.026,), while SWd showed a significant difference only between the NP and CP group (NP vs CP; P = 0.001). The CT values were significantly different between the CP and NP/ECP groups (NP vs CP; P = 0.0006, ECP vs CP; P = 0.0027). CONCLUSION: Pancreatic SWE and CT values were helpful in the diagnosis of chronic pancreatitis. SWd may reveal status changes in ECP.


Assuntos
Técnicas de Imagem por Elasticidade , Pancreatite Crônica , Humanos , Técnicas de Imagem por Elasticidade/métodos , Pancreatite Crônica/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Ultrassonografia , Fígado
10.
Dig Endosc ; 35(1): 47-57, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35702927

RESUMO

Urgent or emergency endoscopic retrograde cholangiopancreatography (ERCP) is indicated for gallstone-induced acute cholangitis and pancreatitis. The technique and optimal timing of ERCP depend on the disease state, its severity, anatomy, patient background, and the institutional situation. Endoscopic transpapillary biliary drainage within 24 h is recommended for moderate to severe acute cholangitis. The clinical outcomes of biliary drainage with nasobiliary drainage tube placement and plastic stent placement are comparable, and the choice is made on a case-by-case basis considering the advantages and disadvantages of each. The addition of endoscopic sphincterotomy (EST) is basically not necessary when performing drainage alone, but single-session stone removal following EST is acceptable in mild to moderate cholangitis cases without antithrombotic therapy or coagulopathy. For gallstone pancreatitis, early ERCP/EST are recommended in cases with impacted gallstones in the papilla. In some cases of gallstone pancreatitis, a gallstone impacted in the papilla has already spontaneously passed into the duodenum, and early ERCP/EST lacks efficacy in such cases, with unfavorable findings of cholangitis or cholestasis. If it is difficult to diagnose the presence of gallstones impacted in the papilla on imaging, endoscopic ultrasonography can be useful in determining the indication for ERCP.


Assuntos
Colangite , Cálculos Biliares , Pancreatite , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Cálculos Biliares/diagnóstico , Cálculos Biliares/diagnóstico por imagem , Esfinterotomia Endoscópica/métodos , Colangite/diagnóstico , Colangite/etiologia , Colangite/cirurgia , Pancreatite/complicações , Pancreatite/diagnóstico , Doença Aguda
11.
J Hepatobiliary Pancreat Sci ; 30(3): 401-407, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36043228

RESUMO

BACKGROUND/PURPOSE: A peroral cholangioscope (POCS) can allow direct visualization of the biliary mucosa and its use is becoming more widespread due to improvements in functionality, image quality, and operability, as well as the development of related devices. Recently, a novel mother-baby peroral cholangioscope (nMB-POCS) with a large (2-mm) accessory channel has been developed. In this study, we evaluated the feasibility of this novel POCS in a dry simulation and animal model. METHODS: We evaluated the ease of insertion and maneuverability of the nMB-POCS, the image quality, and the passage of the devices into the accessory channel and into the common bile duct in a dry and live porcine model. RESULTS: In both models, the nMB-POCS could be easily inserted into the duodenoscope and into the distal bile duct and hilum. The image quality was good, and it was possible to observe the surface structure and the vascular network of the bile duct mucosa in detail. CONCLUSIONS: The nMB-POCS with its larger accessory channel is expected to improve the efficiency of diagnosis and  treatment, and reduce the procedure time. Clinical studies in patients are warranted.


Assuntos
Procedimentos Cirúrgicos do Sistema Biliar , Laparoscopia , Animais , Suínos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Ductos Biliares , Ducto Colédoco
12.
J Hepatobiliary Pancreat Sci ; 30(4): e20-e21, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36048175

RESUMO

This paper discusses a novel tube placement technique; the "spinning lasso method", in EUS-guided drainage for small pancreatic pseudocysts (PC) with video. In general, the placement of a drainage tube can be difficult in a small PC and the tube often deviates during attempted insertions into the cavity. The technique helps to mitigate this problem.


Assuntos
Pseudocisto Pancreático , Humanos , Pseudocisto Pancreático/diagnóstico por imagem , Pseudocisto Pancreático/cirurgia , Endossonografia/métodos , Drenagem/métodos , Stents
13.
J Hepatobiliary Pancreat Sci ; 30(7): 983-992, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36458423

RESUMO

BACKGROUND/PURPOSE: EUS-guided biliary drainage (EUS-BD) has recently been reported to be a useful salvage technique after ERCP fail. However, data on EUS-BD used for preoperative biliary drainage (PBD) are limited. The aim of this study was to verify the clinical feasibility of EUS-BD for PBD. METHODS: PBD was performed for malignant biliary obstruction in 318 patients at our institution between July 2014 and April 2022. Fifteen (4.7%) of these patients underwent surgical resection after preoperative EUS-BD (HGS 13; HDS 1; AGS with HGS 1) and were retrospectively analyzed. RESULTS: The stent was successfully placed in all 15 cases with a median procedure time of 15 min (technical success rate 100%). The median total bilirubin value decreased significantly from 3.7 before drainage to 0.9 after surgery (p < .001) and cholangitis was well managed (clinical success rate 100%). Surgery was performed at a median of 22 days after drainage, and there were no stent-related adverse events or recurrences of biliary obstruction. Severe surgery-related adverse events occurred in three cases, but none were associated with EUS-BD. The stent was removed during surgery in 12 cases. CONCLUSIONS: EUS-BD can be a feasible and safe alternative method of PBD for malignant biliary obstruction after ERCP fail.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Colestase , Humanos , Estudos Retrospectivos , Estudos de Viabilidade , Colangiopancreatografia Retrógrada Endoscópica/métodos , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Drenagem/métodos , Ultrassonografia de Intervenção , Endossonografia/métodos , Stents/efeitos adversos
14.
Artigo em Inglês | MEDLINE | ID: mdl-36224458

RESUMO

There is a tremendous need for prevention and effective treatment of cancer due to the associated morbidity and mortality. In this study, we introduce sonodynamic therapy (SDT), which is expected to be a new cancer treatment modality. SDT is a promising option for minimally invasive treatment of solid tumors and comprises three different components: sonosensitizers, ultrasound, and molecular oxygen. These components are harmless individually, but in combination they generate cytotoxic reactive oxygen species (ROS). We will explore the molecular mechanism by which SDT kills cancer cells, the class of sonosensitizers, drug delivery methods, and in vitro and in vivo studies. At the same time, we will highlight clinical applications for cancer treatment. The progress of SDT research suggests that it has the potential to become an advanced field of cancer treatment in clinical application. In this article, we will focus on the mechanism of action of SDT and its application to cancer treatment, and explain key factors to aid in developing strategies for future SDT development.

15.
Artigo em Inglês | MEDLINE | ID: mdl-35551555

RESUMO

Pancreatic cancer (PC) has one of the poorest prognoses among solid cancers, and its incidence has increased recently. Satisfactory outcomes are not achieved with current therapies; thus, novel treatments are urgently needed. High-intensity focused ultrasound (HIFU) is a novel therapy for ablating tissue from the outside of the body by focusing ultrasonic waves from multiple sources on the tumor. In this therapy, only the focal area is heated to 80-100 ºC, which causes coagulative necrosis of the tissue, with hardly any impact on the tissue outside the focal area. Although HIFU is a minimally invasive treatment and is expected to be useful, it is not yet generally known. Here, we discuss the usefulness of HIFU treatment for un-resectable advanced PC using the results of previous research, meta-analyses, and systematic reviews on its efficacy and safety. HIFU therapy for un-resectable PC is useful for its anti-tumor effect and pain relief, and is expected to prolong survival time and improve quality of life. Although HIFU for PC has several limitations and further study is needed, this technique can be safely performed on un-resectable advanced PC. In future, HIFU could be utilized as a minimally invasive treatment strategy for PC patients with a poor prognosis.

16.
J Hepatobiliary Pancreat Sci ; 29(6): e57-e58, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35302713

RESUMO

Highlight Interventional endoscopic ultrasound has become widely used although it remains challenging. Nagai and colleagues present the first case of single-session endoscopic ultrasound-guided hepaticogastrostomy and endoscopic ultrasound-guided pancreatic duct drainage, and demonstrate that it is feasible for the management of biliary and pancreatic duct stones in patients with surgically altered anatomy.


Assuntos
Pancreatopatias , Stents , Drenagem , Endossonografia , Humanos , Pancreatopatias/complicações , Pancreatopatias/diagnóstico por imagem , Pancreatopatias/cirurgia , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/cirurgia , Ultrassonografia de Intervenção
17.
J Hepatobiliary Pancreat Sci ; 29(7): 817-824, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35030302

RESUMO

BACKGROUND/PURPOSE: Although the lumen-apposing metal stent (LAMS) is useful for interventional endoscopic ultrasound (EUS) procedures, there has been some concern about the potential for stent-induced adverse events because of the high lumen-apposing force. A newly designed LAMS with less lumen-apposing force has been developed for use with a physician-controlled electrocautery-enhanced delivery system. The aim of this animal study was to evaluate the feasibility of performing interventional EUS using this newly designed LAMS system. METHODS: Endoscopic ultrasound-guided cystogastrostomy was performed using the novel LAMS three times in a wet simulation model. EUS-guided gastroenterostomy and EUS-guided gallbladder drainage were then performed using the system in four pigs. RESULTS: The LAMS was successfully placed in all three EUS-guided cystogastrostomy procedures using the wet simulation model and in all four EUS-guided gastroenterostomy and gallbladder drainage procedures in the animal model. In the 3 weeks following the procedure, eating behavior was normal in all animals and there were no adverse events. The stents remained patent during this time and were removed without difficulty. The fistula was mature in all cases and a standard upper gastrointestinal endoscope was easily advanced via the fistula to observe the afferent and efferent loops or the lumen of the gallbladder. Necropsy confirmed complete adhesion between the stomach and the wall of the jejunum or gallbladder. CONCLUSIONS: Our study findings demonstrate the feasibility of this new LAMS system and its potential clinical value for interventional EUS.


Assuntos
Anastomose Cirúrgica , Eletrocoagulação , Endossonografia , Implantação de Prótese , Stents , Ultrassonografia de Intervenção , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Animais , Fístula do Sistema Digestório/etiologia , Fístula do Sistema Digestório/cirurgia , Drenagem/instrumentação , Drenagem/métodos , Eletrocoagulação/instrumentação , Eletrocoagulação/métodos , Endossonografia/instrumentação , Endossonografia/métodos , Vesícula Biliar/cirurgia , Jejuno/cirurgia , Modelos Animais , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Estômago/cirurgia , Suínos , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos
18.
Gastrointest Endosc ; 95(4): 760-776, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34678300

RESUMO

BACKGROUND AND AIMS: The optimal electrosurgical unit (ESU) settings for endoscopic papillectomy (EP) have not been investigated. We conducted animal experiments to determine the optimal endoCUT settings with VIO (Erbe, Tübingen, Germany) ESUs and then conducted a small clinical study. METHODS: Dedicated animal experimental models were created. To investigate the incision force, chicken meat was resected with a snare whose handle was a hung weight. To investigate the coagulation effect, a surgical needle electrode was inserted into a pig liver and energized, and to determine changes over time in the coagulation status, simulated EP was performed using a living pig. These experiments were performed using the knife-setting or snare-setting endoCUT modes and various effect, duration, and interval settings and compared with results for ICC (Erbe) ESUs. Based on the results, we performed EP in a small number of patients. RESULTS: The main factor affecting the incision force was duration. The coagulation effect was related to not only effect but also duration. In the endoCUT mode, knife-setting produced a higher incision force and lower coagulation effect. The nondischarge coagulation effect may cause deep ulceration. Based on the animal experiments, we concluded the ideal ESU setting for EP, "VIO EP mode," is knife-setting with high duration, lowest effect, and low interval settings. In the clinical study, there were no significant adverse events such as bleeding, pancreatitis, or perforation. CONCLUSIONS: "VIO EP mode" seems to afford optimal papillectomy. Larger scale clinical studies are needed to accumulate further data and make clinical comparisons with the ICC ESU.


Assuntos
Experimentação Animal , Eletrocirurgia , Animais , Eletrocirurgia/métodos , Humanos
19.
Intern Med ; 61(12): 1843-1848, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34866100

RESUMO

We herein report two cases of hemorrhagic ampullary lesions in which endoscopic papillotomy was performed to control bleeding and resulted in successful treatment. Both patients were pathologically diagnosed with an underlying pathology characterized by inflammatory cell infiltration and capillary proliferation. They also had disposing factors for bleeding, such as antithrombotic therapy and idiopathic thrombocytopenic purpura. Endoscopic treatment was selected because the risk of surgical resection was high due to the patients' hemorrhagic condition. Both patients were successfully treated without any serious adverse events and had an uneventful postoperative course with no relapse of bleeding.


Assuntos
Ampola Hepatopancreática , Hemorragia , Ampola Hepatopancreática/cirurgia , Hemorragia/terapia , Humanos , Esfinterotomia Endoscópica , Resultado do Tratamento
20.
J Hepatobiliary Pancreat Sci ; 29(6): e59-e60, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33711188

RESUMO

Highlight Endoscopic ultrasound-guided gastrojejunostomy using a lumen-apposing metal stent has recently emerged as an alternative to surgical gastrojejunostomy and endoscopic gastroduodenal stenting, but there are no long-term follow-up reports. Tsuchiya and colleagues present the first report of endoscopic ultrasound-guided gastrojejunostomy for benign gastric outlet obstruction, showing a good long-term clinical course without complications.


Assuntos
Obstrução Duodenal , Derivação Gástrica , Pancreatite , Doença Aguda , Obstrução Duodenal/diagnóstico por imagem , Obstrução Duodenal/etiologia , Obstrução Duodenal/cirurgia , Endossonografia , Humanos , Pancreatite/complicações , Pancreatite/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...